Appendix C: Bar Code Settings
Decoded (Internal) Scanners
Codabar
selected lengths. Length within a range allows you to decode a code type within a specified
range from 4 to 55.
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-15 for details.
C.2.13 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any length, Length within a range, One discrete length
or Two discrete lengths. The length of a code refers to the number of characters (i.e., human
readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where
you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a selected
length. Choosing Two discrete lengths allows you to decode only those codes containing two
selected lengths. Length within a range allows you to decode a code type within a specified
range from 5 to 55.
CLSI Editing
When enabled, this parameter strips the start and stop characters and inserts a space after the
first, fifth, and tenth characters of a 14-character Codabar symbol.
NOTIS Editing
When enabled, this parameter strips the start and stop characters from decoded
Codabar symbol.
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Note: Symbol length does not include start and stop characters.