Chapter 6: Peripheral Devices & Accessories
Powered Cradle Installation
196 Psion Teklogix 7535 G2 Hand-Held Computer User Manual
6.11.6 Powered Cradle Installation
The powered cradle option is designed to allow the 7535 G2 to be powered by a vehicle bat-
tery. The battery installed in the 7535 G2 is also recharged by the vehicle battery. This
option accepts DC power sources over the range 12V to 80V.
The 7535 G2 picker cradle can be ordered with the powered cradle option installed, or it can
be retrofitted later at an authorized Psion Teklogix service depot.
The 7535 G2 charging LED (see “Charge LED” on page 53) indicates that external power is
available, and it also indicates the charging status of the internal battery.
The metal chassis of the picker cradle must be connected directly to the chassis of the vehi-
cle. A safety ground lug (clearly labelled on the rear of the cradle chassis) is provided for
this purpose. The grounding strap must connect from the ground stud on the picker cradle to
a solid, reliable contact point on the main portion of the vehicle chassis. It must not be con-
nected to battery negative or a terminal block. This grounding strap ensures that if there is a
fault in the vehicle wiring or in the picker cradle power module, the picker cradle cannot be
at a hazardous voltage with respect to the vehicle chassis.
Connection between the picker cradle ground lug and the vehicle chassis should be done
with a 16 gauge ground strap (ground wire). Connect the ground strap to the picker cradle
utilizing the ground lug hardware supplied with the picker cradle and a #10 heavy duty wire
crimp ring terminal. Torque the ground lug hardware to 23.0 +/- 2.0 in-lbs. Connect the
other end of the ground strap to a solid, reliable point on the main portion of the vehicle
chassis, ensuring a solid electrical connection.
As with other vehicle cables, the routing of the ground strap should be carefully considered
to ensure it does not pose a hazard to the operator or the safe operation of the vehicle. If nec-
essary, secure the ground strap with cable ties or some other mechanical means to prevent
loops or loose lengths of wire that could catch on stationary items when the vehicle is
in motion.
Warning: Applying a voltage above 90VDC or reversing polarity may result in perma-
nent damage to the cradle power option and will void the product warranty.
TO AVOID ELECTRIC SHOCK when the powered cradle option is
installed, always ensure
that the rear panel ground lug on the picker cradle is
connected to the vehicle chassis. Failure to do this could result in serious
injury or death.