Chapter 6: Peripheral Devices & Accessories
Combo Charger
184 Psion Teklogix 7535 G2 Hand-Held Computer User Manual
6.5.5.3 Indicator Flashing Red
If the indicator flashes red:
Remove all batteries and disconnect the mains power cable.
Wait at least 20 seconds, and then plug the cable in again.
If any of the charge slot LEDs continue to flash red, the charger is defective and requires ser-
vice. If all indicators are flashing red, there is a power supply problem and the charger
requires service.
6.5.5.4 Power LED Does Not Light Up
Remove all batteries, and unplug the charger.
Connect another device to the mains outlet to ensure there is power.
Remove the IEC mains power cable from the charger, and check it for damage.
Reconnect the mains cable in the charger and mains outlet.
6.5.5.5 Indicator Does Not Light When Battery Installed
Remove the battery, and clean the contacts on the battery and the charge slot.
Reinstall the battery, and check that it is fully seated in the slot.
Inspect the charge slot contacts for damage (are they bent, flattened, twisted or broken).
Try inserting a battery that you know to be working in the charger slot.
Reconnect the mains power cable, and check that the slot indicator flashes at powerup.
6.6 Combo Charger
The 7535 G2 combo charger is a desktop charger designed to charge the 7535 G2 internal
battery along with a spare battery pack. The combo charger provides sufficient power to
operate and fast charge the 7535 G2 internal battery, while recharging the spare battery pack.
6.6.1 Installation
Keep the combo charger away from excessive dirt, dust and contaminants. The combo
charger will not charge batteries outside an ambient temperature range of 5° C to 39° C (41°
F to 102° F). It is recommended that this charger be operated at room temperature between
18° C and 25° C (64° F to 77° F) for maximum performance.
After unpacking the unit:
Note: The combo charger is shipped with a user manual. It is critical that this manual be
reviewed for additional information and updates.