C-16 Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Appendix C: Bar Code Settings
Decoded (Internal) Scanners
EAN 13
Decode Performance
If this parameter is set to on, one of three decode levels assigned to the Decode Performance
Level parameter can be selected.
Decode Perf. Level
This parameter provides three levels of decode performance or “aggressiveness” for Code
128 symbols. Increasing the performance level reduces the amount of required bar code ori-
entation, allowing you to scan at an angle horizontal to the bar code. This is useful when
scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce
decode security. There is a limitation that it can only be used with one fixed length.
When you double-tap on this parameter, a dialog box is displayed in which you can enter a
decode performance level of between 1 and 3.
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-15 for details.
C.2.7 EAN 13
Enabled
Set this parameter to on to enable “EAN 13”.
Add/Remove Data
Refer to “Add/Remove Data” on page C-15 for details.
C.2.8 EAN 8
Enabled
Set this parameter to on to enable “EAN 8”.
EAN-8 Zero Extend
When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols,
making them compatible in format to EAN-13 symbols. Disabling this parameter returns
EAN-8 symbols to their normal format.