Psion Teklogix WORKABOUT PRO Hand-Held Computer User Manual 129
Chapter 7: Expansion Modules
Installing An SE 1223HP Scanner
Remove the stylus and then, remove the end-cap at the top of the
WORKABOUT PRO.
Slide the SW1401 switch to the left to shut off internal battery power.
Remove the back plate from the unit.
A scanner flex cable is already attached to the WORKABOUT PRO. You need to
connect the flex cable to the internal scanner module.
On the scanner module, pull the tabs on either side of the connector up.
Using pincers, insert the flex cable into the connector on the scanner
module.
Push the connector tabs down to secure the flex cable in place.
Figure 7.8 Attaching The Flex Cable To The Scanner Module
Fit the scanner module over the back of the WORKABOUT PRO – it
replaces the back plate of the unit.
Fasten the module in place with the screws provided.
Scanner
Connector
Module
Flex
Cable