Chapter 5: Settings
Decoded (HHP)
158 WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual
5.27.2.15 Interleaved 2 of 5
Enabled
Set this parameter to on to enable “Interleaved 2 of 5”.
Check Digit
When this parameter is set to Validate only, the integrity of a symbol is checked to
ensure that it complies with specified algorithms.
If “Check Digit” is set to Validate and Transmit, the check digit is validated and
transmitted with the data.
Setting this parameter to None disables this function.
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable
characters), including check digit(s). Double-tapping on these parameters displays a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 80.
Field Size/Char
Refer to page 136 for details.
5.27.2.16 Matrix 2 of 5
Enabled
Set this parameter to on to enable “Matrix 2 of 5”.
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable
characters), including check digit(s). Double-tapping on these parameters displays a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 80.
Field Size/Char
Refer to page 136 for details.