Appendix C: Bar Code Settings
EAN 13 Settings
Psion Teklogix NEO Hand-Held Computer User Manual C-23
Check Digit Verification
The available options for this parameter are Disabled or French CIP. This parameter uses
the specified algorithm of the option you've chosen to ensure the integrity of the symbol data
before transmitting. If the data does not contain that algorithm, the data is not transmitted.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).
Length Restriction
Refer to “Length Restriction” on page C-7 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-8 for details.
C.2.5 EAN 13 Settings
Enabled
Set this parameter to on to enable EAN 13.
ISBN Conversion
When this parameter (International Standard Book Number) is enabled, the first 3 characters
(‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Add/Remove Data
Refer to “Add/Remove Data” on page C-8 for details.
C.2.6 EAN 8
Enabled
Set this parameter to on to enable EAN 8.
Note: French CIP (French pharmaceutical) is only used with bar codes containing
7 characters.